Excellent Valves for Isolation & Control

Language

CV1500 Low Flow Control Valve

CV1500 Low Flow Control Valve

Valve Type:                                                 Low flow control valve with cavitation elimination

 

Valve Nominal Size:                                  DN15 through DN80; 0.5 inch through 3 inch

 

Pressure Rating:                                         PN100, 160, 250; ANSI Class 600, 900, 1500

 

Body Style:                                                  Full guided globe

 

Trim Type:                                                   Unbalanced multi-grooves plug

 

Flow Direction:                                           Flow under the plug (recommended); Flow over the plug

 

Flow Characteristic:                                   Equal percentage EQ%; Linear

 

Temperature Range:                                  From -30°C to 500 °C

 

Seat Leakage:                                               ANSI VI

 

Actuator:                                                       Pneumatic cylinder actuator; Pneumatic diaphragm actuator;

                                           Electric actuator

 


 

Description & Features

CV1500 Low Flow Control Valve Plug

 

 

CV1500 low flow control valve is designed to provide smooth and precise control of small Cv application, to solve the problem as cavitation, abrasion, vibration, noise and poor performance associated with traditional single-seat valve applicable in high differential pressure and low flow service.

 

Low flow control valve’s Cv value can be low to 1 × E-3.

 

Plug structure is full guided: stable motion, and eliminate plug deforming or bending by unbalanced force.

 

Very small flow area: clearance fit between the conical part of plug with the conical part of seat, then it works low flow controlling precise and steady. Better to reduce the fluid abrasion, by flow direction to open and streamline shape of plug head.

 

Multi-stages pressure reducing structure: continually expanding grooves on the conical part of plug, special applied in high differential pressure application. Pressure-unbalanced plug for tight seal, seat retainer has pressure relieving groove to avoid fluid pressure broken seal gasket. Flow paths on seat retainer is orifice design, all of valve’s flow paths is calculated and simulated by CFD computational fluid dynamics software under different working conditions.


 


 

SPEC SHEET

West Control on Social Web:
Copyright @ 2016.West Control All Rights Reserved
loading...